Power and error displays on the control unit

Symbol

Response

Possible cause

Action

Lights up red

After the first 100 operating
hours, then after every 200 op-
erating hours.

Carried out only by TYROLIT Hydrostress AG
or an authorised representative

Lights up red

Fault:
- current overload
- short circuit
- earth fault Main motor
- defective feed motor

The control unit will not start.

X

Check network connection.

X

Check cable.

X

Replace feed motors.

X

Contact TYROLIT Hydrostress AG customer service.

Lights up red

Defective
- main contactor
- brake resistance
- over current Motor
- CAN fault
- group fault

The control unit will not start.

X

Contact TYROLIT Hydrostress AG customer service.

X

Check network connection.

Lights up red

Over heated
- cooling element
- control unit
- main motor

The control unit will not start.

X

Check cooling. Wait until it can be restarted. Before starting
press the reset button.
(Water cooling see page 20)

X

Avoid direct contact with sun light.

Lights up red

Phase missing

The drive unit will not start or switches off during operation.

X

Check the mains fuse in the distribution box and switch it on
if necessary.

X

Have the site power supply checked.

X

Have the extension cables, plugs and sockets
checked for faults.

Lights up red

The EMERGENCY STOP has been
activated
- CAN fault

X

Deactivate the EMERGENCY STOP.

X

Contact TYROLIT Hydrostress AG customer service.

Lights up red

Feed potentiometer not in zero

position

The control unit will not start.

X

Set the feed potentiometer to 0.