Switching off the control unit wse2226, Blowing out the water – Diamond Products WSE2226 User Manual
Page 12

TYROLIT
Hydrostress AG
Page 12
Manually adjusting the feed speed
9
Control unit WSE2226 has started
X
Select the required feed speed via the feed potentiometer (6).
Feed stop
So that the joystick does not have to be held in position during the travel feed motion the travel
feed can be locked.
Proceed as follows:
X
Push the joystick in the desired travel direction and at the same time press the locking
switch (1).
X
When the joystick and the locking switch are released the feed is locked.
In order to release the feed lock, move the joystick slightly in any desired direction.
Switching off the control unit WSE2226
Proceed as follows:
X
Switch off electric motor (7) On / Off main motor.
X
Turn off cooling water, switch (2) Water On / Off.
X
Close water valve on control unit WSE2226.
X
Turn the start switch (5) on the remote controller to the 0 position.
X
Switch off the control unit WSE2226 using the main switch (11).
Only stop the wall saw WSE2226 using the EMERGENCY STOP function in an emergency.
CAUTION
Frost damage to control unit WSE2226!
Heat damage to control unit WSE2226!
X
Blow out any water if there is a risk of frost (see chapter 4.9, Blowing out water).
X
Direct sunlight on the WSE2226 control unit must be avoided.
Blowing out the water
9
Main switch is set to OFF
X
Disconnect the mains plug.
X
Disconnect all water lines.
X
Connect blow out pump to the water nipple.
X
Blow out water until all of the cooling water has been removed.
X
Remove the pump.
4.7.1
4.7.2
4.8
4.9