beautypg.com

0 installation, Warning, Caution – Detroit Radiant Products Company MP Series User Manual

Page 5

background image

5

TH-PUI

Series

2.0

Installation

Installation

1

Using the template on page 16, mark hole locations for mounting and wire inlets.

2

Drill mounting holes. Ensure that the wires will feed through the wire opening in the base of the thermostat.

3

Remove cover from the base by unscrewing the two (2) #1 Phillips screws from the base. Carefully disconnect

ribbon connector from the base by pulling it straight off of the board.

Forcing or straining the ribbon cable will cause damage to the unit.

4

Fasten base snugly to the wall or mounting surface utilizing the mounting holes provided. Level as necessary

for visual purposes (unit being out of level will not affect performance).

5

Route 18 ga. shielded thermostat wire through the hole provided in the back of the base.

6

Connect wires to the terminal block following the appropriate wiring diagram.

7

Carefully re-connect the ribbon connector to the base and set the cover in place. Secure with the six (6)

screws provided.

WARNING

!

Electrical Shock Hazard

Disconnect power at the main fuse or breaker prior to installing this unit.

CAUTION

!