DATASHEET

LIT4318_3_US

Badge Name

Environmental TLD 110

Environmental TLD 814

Leak Test

Badge Type

17= Environmental 110*

20= Environmental 814*

Leak Test kit*

Description

4-element Harshaw TLD
(2 CaF:Dy [TLD200] and 2 LiF:Mg,
Ti [TLD100] elements)

4 Element Panasonic TLD
(1LiBO:Mn [TLD800] and 3 CaSO:Dy
[TLD900] elements)

Gas proportional detector
Sodium iodine detector

Manufacturer

Thermo Electron RMP

Panasonic

n/a

Accreditations/Approvals/
Licenses

ANSI N545-1975

ANSI N545-1975

n/a

Holder Type

Area with wall hanger
Area with clip

Clamshell (clip, loop, or loop + clip)
Clamshell wrist
Clamshell area with wall hanger
SoftPak (wrist, area, wall hanger)

n/a

Wear Location

Fence lines, trees, buildings

Area, equipment

n/a

Minimum Reportable
Dose

n/a

n/a

0.001 μCi (37 Bq)

Useful Dose Range

0.05 mGy - 5 Gy

0.05 mGy - 5 Gy

n/a

Energy Response

Photon (TLD100): 40 keV - 6 MeV
Photon (TLD200): 180 keV - 6 MeV

Photon: 180 keV - 6 MeV

n/a

*Not accredited for personnel monitoring