ENVIRONMENTAL TLD

Precision reliability to withstand the toughest
environmental stresses

Environmental dosimeters are well suited to monitor low-
level gamma radiation and withstand the most intense
environmental situations. This dosimeter is designed
for outdoor applications and may be used to measure
radiation for site characterization, at site boundaries for
regulatory compliance, and to monitor public exposure.
Issued reports provide easy comparison to ion chamber
results.

The Environmental TLD Dosimeter, encased in a holder
that protects against moisture, can be attached to fences,
gates, trees, or other objects in the environment for quick
access.

LEAK TEST

Reliable radiation source for leak testing

The Dosimetry Services Division provides complete Leak
Test kits for reliable testing of alpha, beta, or gamma
emitting radiation sources. Once completed, you will
receive a comprehensive report that lists each source
tested and the results in microcuries (μCi).

An instruction sheet provides step-by-step instructions.

TECHNICAL SPECIFICATIONS:

Badge Name

High Dose Dosimeter

CR 39 Neutron

REMtrack Wallet Card

Badge Type

11 = LiF Loose Chip*
12 = LiF Chipstrate*

15 PB = TLD760 with CR39

1, 2, 3

15 DB = TLD760 with CR39

1, 2

25 = TLD760 with 115 In* and CR39
35 = Genesis Ultra TLD

1, 2

21= one LiF chip

1

22= two Lif chips*
23= one Lif chip with 115 In*
24= two Lif chips with 115 In*

Description

Single chip of

n

LiF:Mg, Ti

(TLD100 loose chip or a
bar-coded chipstrate)

Plastic polymer used to as a track
detector

Single chip of

n

LiF:Mg, Ti

(TLD100 loose chip)

Manufacturer

Thermo Electron RMP

PPG

Thermo Electron RMP

Accreditations/Approvals/
Licenses

n/a

NVLAP (Code: 100555-0)
HSE (United Kingdom)

NVLAP (Code: 100555-0)

Holder Type

High dose
Loose chips- no holder
Bag holder- chips placed in a
plastic bag

Whole body
Wrist
Area
Plastic bag

Personal card (loop through card for
hanging)

Wear Location

Area, equipment

Whole body, area

Area, whole body

Minimum Reportable
Dose

20 mrem (0.20mSv)

20 mrem (0.20 mSv)

20 mrem (0.20 mSv)

Useful Dose Range

Up to 500 krad (5kGy)

20 mrem - 5 rem (0.20 - 50 mSv)

20 mrem - 1000 rad (0.20 mSv - 10Gy)

Energy Response

Beta (MAX) 0.766 MeV - 5 MeV
Photon 20 keV - 6 MeV

Neutron: 200 keV - 6 MeV**

Beta (MAX) 0.766 MeV - 5 MeV
Photon 20 keV - 6 MeV

*Not accredited for personnel monitoring
**Neutron energies up to 20 MeV with CR39 and special calibration
1: NVLAP (Code 100555-0) accredited configuration
2: HSE accredited configuration
3: CNSC accredited configuration