Physical characteristics, Particulate, Filter type: fi berglass – Mirion Technologies PIS 203S User Manual
Page 2: Effi ciency: > 99.95, Iodine, Cartridge type: silver zeolite, Effi ciency: > 99.99% (for methyl iodine), Concentration on fi lter: 3.7 10, Bq/m, Μci/cc) environmental characteristics

Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
Route d’Eyguières
FR-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna, GA 30082
USA
T +1 770 432 2744
F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a
DE-80687 Munich
Germany
T +49 (0) 89515 13-0
F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu
Zhabei District, Shanghai 200436
PR of China
T +86 21 6180 6920
F +86 21 6180 6924
PIS 203S
Samplers
PHYSICAL CHARACTERISTICS
●
Particulate:
○
Filter type: fi berglass
○
Effi ciency: > 99.95%
●
Iodine:
○
Cartridge type: silver zeolite
○
Effi ciency: > 99.99% (for methyl iodine)
●
Lead shielding: 4 π/15 cm (4 π/5.9 in)
●
Concentration on fi lter: 3.7 10
+7
to 3.7 10
+12
Bq/m
3
(10
-3
to 10
+2
μci/cc)
ENVIRONMENTAL CHARACTERISTICS
●
Long term temperature:
+10°C to +40°C (+50°F to +104°F)
●
Periodic temperature:
-5°C to +55°C (+23°F to +131°F)
●
Pressure: 860 to 1060 hPa
●
MTBF: > 20 000 hours, with preventive maintenance
PNEUMATIC CHARACTERISTICS
●
Standard fl ow rate: 1 l/min
MECHANICAL CHARACTERISTICS
●
Dimensions: 1214 mm x 650 mm x 740 mm
(48 in x 25.6 in x 29.1 in)
●
Weight: ~ 750 kg (~ 1650 lb)
●
Color: gray RAL 7030 (decontaminable paint)
●
Inlet tube connection: Ø 6.3 mm OD (1/4 in)
●
Outlet tube connection: Ø 6.3 mm OD (1/4 in)
ELECTRICAL CHARACTERISTICS
●
Power supply: refer to possible versions
SIGNALING
●
Alphanumeric display: measurement, status…
●
Sound alarm: buzzer 90 dBA at 1 meter
●
Visual alarm: 3 lights (red, yellow, green)
REFERENCE STANDARDS
●
Environmental: RG 1.97
●
EMC: 2006/95/CE, 2004/108/CE
VERSIONS
●
230 Vac or 230 Vac + 400 Vac 3Ø or 120 Vac + 400
Vac 3Ø
●
Single module or dual unit
●
Heat tracing with heat control unit, temperature
sensors, thermal insulation and heating cartridge
ACCESSORIES
●
Shielded transport cart
●
Sampling handling tool
●
Filter paper
www.mirion.com
145019EN-C