beautypg.com

Mirion Technologies PIS 203S User Manual

Radiation monitoring systems, Pis 203s, Shielded particulate and iodine sampler

background image

Featuring:

radiation monitoring

systems

A Mirion Technologies Division

PIS 203S

Samplers

PIS 203S

Shielded Particulate and Iodine Sampler

The PIS 203S sampler forms part of the RAMSYS

product line. It has been developed to sample air

effl uents under accident conditions conforming to the

requirements set forth by RG 1.97. One sampler for

batch sampling or dual samplers for continuous sam-

pling are available with or without heat tracing. The

sample fl ow rate through the sampler is measured

and totalized. The collected activities of particulates

and iodine are periodically analyzed in a laboratory as

needed.

The PIS 203S is typically used in conjunction with

noble gas monitor and an aeraulic skid that automa-

tically control the operation from standby to active

sampling as applicable.

APPLICATIONS

• Effl uent release monitoring

• Post-accident operations

RELATED MONITORS

• PIS 204L: « light » version

• PIS 205L: « light » version with fl ow rate control

• NGM 203S: low range noble gas monitor

• NGM 204S: high range noble gas monitor

• PING 206S: particulate, iodine and noble gas

monitor

FEATURES

Available for batch or continuous sampling acquisition

version (single or dual PIS 203S units)

Automatic start up in accident confi guration

Heat tracing available when required

Provided with manipulation tools and lead shielded

transport cart

Heavily shielded for ALARA radiation considerations

Available under 10 CFR 50 App.B, ASME NQA-1 and

IEC61226 programs for safety related application