Detector pulses: > 30 ns up to 5e6 cps, 5v standard pulses: >1 µs up to 4e5 cps, Dc currents: from 0.1 pa to 1 ma – Mirion Technologies RMS 250 User Manual
Page 4: Analog signals: 0/4 ma, Binary signals, 24v-logic, contacts, namur-sensors, Detector supply, Linear or logarithmic analog outputs, Measuring range to be adjusted with parameters, 0 v internal, optional analog indicator

Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.
Mirion Technologies (MGPI) SA
Route d’Eyguières
FR-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna, GA 30082
USA
T +1 770 432 2744
F +1 770 432 9179
Mirion Technologies (MGPI H&B) GmbH
Landsberger Strasse 328a
DE-80687 Munich
Germany
T +49 (0) 89515 13-0
F +49 (0) 89515 13 169
Mirion Commercial (Beijing) Co., Ltd.
Shanghai Jiangchang Commercial Branch
Room 801, 78 Jiangchang SanLu
Zhabei District, Shanghai 200436
PR of China
T +86 21 6180 6920
F +86 21 6180 6924
RMS 250
Radiation Monitoring
www.mirion.com
144982EN-B
SIGNAL PROCESSING CHANNELS
for different
applications:
DPK 251 Digital Pulse Channel for dose rate and
activity monitoring with 2 or 4 signal paths
DFK 251 Digital Filter Channel for particulate and
iodine monitors
DEK 251 Digital Effl
uent Monitoring Channel e.g.
for post accident monitors
DAK 250 Digital Start-up Channel for applications in
category A
INPUT SIGNALS
●
Detector pulses: > 30 ns up to 5e6 cps
●
5V standard pulses: >1 µs up to 4e5 cps
●
DC currents: from 0.1 pA to 1 mA
●
Analog signals: 0/4 ... 20 mA
●
Binary signals:
○
24V-logic, contacts, NAMUR-Sensors
●
Detector supply:
○
0 ... 1 kV, 2 mA or 0 ... 2 kV, 1 mA or 0 ... 4 kV, 0.5 mA
POWER SUPPLY
●
18 ... 33 VDC, approx. 1.6A at 24 VDC or
●
230 VAC or 115 VAC +10%/-15%; 48...62 Hz,
approx. 40 VA
OUTPUT SIGNALS
●
Linear or logarithmic analog outputs:
○
Measuring range to be adjusted with parameters
○
0 ... 10 V internal, optional analog indicator
○
0 or 4 ... 20 mA, 0 ... 600 Ω load, fl oating
●
Up to 20 different alarms, adjusted by parameters:
○
Low or high alarm to be selected for all variables
○
Threshold and hysteresis adjustable
●
Binary outputs, e.g. for alarms, status signals
relay change overs, 60V/0.5A or 125V/1A
ENVIRONMENTAL CONDITIONS
●
Ambient temperature (modules): 0 ... 70°C
(32 ... 158°F)
●
Storage temperature: -30 ... 85°C (-22 ... 185°F)
●
Humidity: < 95%
●
Seismic conditions: ≤5 g, 5 ... 100 Hz
●
Mechanical stress: ≤30 g, 11 ms
MECHANICAL CONSTRUCTION
●
19” modular system according to IEC 60297
●
Printed board size: 100 mm × 160 mm (3.9 in x 6.3 in)
●
Front panels: 20 mm × 128 mm (0.8 in x 5 in)
or multiples
●
Rack size (W×H×D): 483 mm × 133 mm × 280 mm
(19 in x 5.2 in x 11 in)
½-19” wall mount housing
19”-6U wall mount housing