Liquid monitoring according to kta 1504 – Mirion Technologies RMS 250 User Manual
Page 2

RMS 250
Radiation Monitoring
Dose Rate Monitoring, Area Monitoring according to KTA 1501 and KTA 1506
Meas. Range
(Sv/h)
Detector
Detector Temperature
Check
Source
Detector Cable
Signal Processing
Signal Paths
Continuous
1h max.
1e-3 ... 1e+5
1e-5 ... 1e+5
KG 50 SEC
KG 80 PEF
0 ... 135°C
-25 ... 100°C
205°C / 3h
120°C
ch. vol.
2 x cer. coax
4 x coaxial
NV102 + DPK251·K2xxx
NV102P + DPK251·K2xxx
1 ... 4
1 ... 4
1e-7 ... 1
1e-6 ... 1
KG 122 SBL
KG 122 PEF
0 ... 80°C
0 ... 100°C
120°C
TKA 17
ch. vol.
2 x coaxial
4 x coaxial
NV102 + DPK 251·K2xxx
NV102P + DPK251·K2xxx
1 ... 4
1 ... 4
1e-7 ... 100
1e-7 ... 100
KG 151 REZ
KG 220 SEU
-25 ... 150°C
-30 ... 120°C
180°C
165°C
TKA 15
TKA 16
2 x coaxial
2 x coaxial
NV102 + DPK 251·K2xxx
NV102 + DPK251·K2xxx
1 ... 4
1 ... 4
1e-7 ... 0.3
KG 220 EEM
0 ... 80°C
TKA 16
2 x twist.pair
DPK 251 K12xx/14xx
1 ... 4
1e-7 ... 1e-2
ZG 50 A1
-25 ... 70°C
TKA 52
2 x twist.pair
DPK 251 K12xx/14xx
1 ... 4
Monitoring of Radioactive Noble Gas according to KTA 1502 and KTA 1503.1
Meas. Range for
Xe-133 (Bq/m
3
)
Detector
Measuring
Vessel
Lead Shelding
Check
Source
Detector
Cable
Signal Processing
Signal Paths
2e+3 ... 1e+9
1e+4 ... 1e+10
SB 150
SB 40
RSD 275
RSD 200
RSA 481/482
RSA 310/311
TKA 61
TKA 61
TKK 05
TKK 05
DPK 251·K52xx/54xx
DPK 251·K52xx/54xx
1 ... 4
1 ... 4
Liquid Monitoring according to KTA 1504
Meas. Range for
Cs-137 (Bq/m
3
)
Detector
Meas. Vessel
or Principle
Lead
Shelding
Check
Source
Detector
Cable
Signal Processing
Signal
Paths
3e+3 ... 3e+8
5e+3 ... 1e+9
typ. 1e+4 ... 1e+10
SG 65 M
SG 65 M
SG 65 M
RSD 135
RSD 221
Off line
-
RSA 428
Proj. spec.
TKA 54
TKA 54
TKA 54
TKK 05
TKK 05
TKA 05
DPK 251·K52xx/54xx
DEK 251 / DPK 251
DPK 251·K52xx/54xx
1 ... 4
1 ... 4
1 ... 4
Monitoring of Radioactive Aerosols and Iodine according to KTA 1502 and KTA 1503.1
Detected
Activity
Measuring Range
(Bq/m
3
)
Monitor and Detector
Check
Source
Detector Cable
Signal Processing
Signal
Paths
Beta aerosols
Gamma aerosols
Iodine
2 ... 1e+5 for Cs-137
1 ... 1e+4 for Cs-137
1 ... 1e+4 for I-131
AD 24
AG 24
JD 24
SB 40
SG 65 M
SG 65 M
TKA 47
TKA 47
TKA 10
TKK 05
TKK 05
TKA 05
DPK 251·K10x
DPK 251·K30x
DPK 251·K40x
1
1
1
Monitoring of Steam Generator Leakages according to KTA 3501
Detected
Activity
Measuring Range
(Bq/m
3
)
Monitor and Detector
Check
Source
Detector Cable
Signal Processing
Signal
Paths
N-16
Main steam line
1 ... 1e+5
SG 66
TKA 54
TKK 05
DAK 250-i
1
Stack Monitoring for Post Accident Conditions according to KTA 1503.2
Detected
Activity
Measuring Range
(Bq/m
3
)
Monitor
Detector
Check
Source
Detector Cable
Signal Processing
Signal
Paths
Aerosols
Iodine-131
100 ... 2e+8 (1e+11)
20 ... 2e+7 (8e+11)
FA/J 51 SG
SG 65 M
TKA 63
TKK 05
DEK 251.K20x
3
Xenon-133
1e+8 ... 1.5e+14
8e+5 ... 3.7e+15
RSD 211
(NGM 203)
KB 100
CHMC 01
TKA 61
TKA 70
TKK 12
NV102 + DPK251
NV103 + DPK251
1 ... 4
1 ... 4