Display units: msv, μsv or mrem, Neutron measurement, Dose rate display: 0.1 msv/h to 10 sv/h – Mirion Technologies DMC 2000GN User Manual
Page 2: Measurement range: 1 μsv/h to 10 sv/h, Gamma measurement, Rate display: 10 μsv/h to 10 sv/h, Energy range: 50 kev to 6 mev, Linearity, Accuracy: <10, Mechanical characteristics dimensions

Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
BP 1
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technolgies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
DMC 2000GN
Active Dosimetry - Dosimeters
www.mirion.com
144272EN-C
PHYSICAL CHARACTERISTICS
Compliant to IEC 61526 Ed2 for gamma and neutron
●
Display units: mSv, μSv or mrem
●
Neutron measurement:
●
dose display: 1 μSv to 10 Sv (0.1 mrem to 1000 rem)
○
dose rate display: 0.1 mSv/h to 10 Sv/h
○
measurement range: 1 μSv/h to 10 Sv/h
○
energy range: 0.025 eV to 15 MeV
○
Gamma measurement:
●
dose display: 1 μSv to 10 Sv (0.1 mrem to 1000 rem)
○
rate display: 10 μSv/h to 10 Sv/h
○
(1 mrem/h to 1000 rem/h) or from 1 μSv/h / 0.1 mrem/h
(extended option)
measurement range: 0.1 μSv/h to 10 Sv/h
○
energy range: 50 keV to 6 MeV
○
linearity:
○
<± 20% up to 1 Sv/h (100 rem/h)
-
<± 30% up to 10 Sv/h (1000 rem/h)
-
accuracy: <10% (
○
137
Cs, ~ 25 mSv/h, including ± 5% of
extended uncertainty K=2)
ELECTRICAL CHARACTERISTICS
Standard calculator battery LiMnO
●
2
CR2450
Autonomy: 9 months typical (8h per day in run mode)
●
MECHANICAL CHARACTERISTICS
Dimensions:
●
87 x 48 x 31 mm (3.4 x 1.9 x 1.2 in) with clip
87 x 48 x 21 mm (3.4 x 1.9 x 0.8 in) without clip
Weight: 80 g (2.8 oz) with battery
●
ENVIRONMENTAL CHARACTERISTICS
Temperature range: -10°C to 50°C (14°F to 122°F)
●
Humidity: < 90 % at 42°C (108°F)
●
Storage: -30°C to 71°C (-22°F to 160°F)
●
Shock, vibration and drop resistant
●
Waterproof IP67
●
Front view
Rear view with the clip
The histogram enables neutron and gamma doses, events, to be recons-
tructed in detail (3800 steps of 10 s, 1 min, 10 min, 1 h or 24 h).
Radiological supervisors can then analyze the data surrounding an
incident.
All parameters change (alarm threshold, calibration factors, ...)
are memorized in the histogram.
Histogram available with DOSIMASS software
Neutron dose display
Neutron dose rate display
Health Physics
Division
Since norms, specifi cations and designs are subject to occasional change, please ask for confi rmation of the information given in this publication.