beautypg.com

3 wire sinking, 4 wire sourcing, 24vdc – Meriam M2110L SMART LEVEL GAUGE User Manual

Page 28: Loop, Ground, 4 wire floating

background image

9R143 Dated 3/2011

26

CURRENT LOOP MODEL LOOP WIRING





























Note: R = Receiving Device
















24 VDC/ 50 mA
Power Supply

+

-

Gauge & Loop Power

R


24VDC

+LOOP

SMART
GAUGE

-

LOOP


GROUND

3 WIRE SINKING

24 VDC/ 50 mA
Power Supply

+

-

Gauge & Loop Power

R


24VDC

+LOOP

SMART
GAUGE

-

LOOP


GROUND

4 WIRE SOURCING

LOOP
+ Power Supply
24 VDC

20mA

-

R

24VDC



+ LOOP

SMART
GAUGE

-

LOOP

GROUND

+





Power Supply
24 VDC/ 30 mA


-

4 WIRE FLOATING