Discontinued – Max Machinery 220, 221 and 222 FLOW METERS User Manual
Page 5

220-000-350 © 2004 Max Machinery, Inc.
Page 5
Troubleshooting, Maintenance
T
ROUBLESHOOTING
:
Problem
Cause
Solution
Material will not pass
Solid particle in
Disassemble and remove
through flow meter.
gears or hardened
particle or clean.
material.
Material flows through
Solid particle in
Disassemble and remove
flow meter, but transmitter
gears.
particle.
does not run and pressure
drop is high.
Material flows through
Frozen or hard
Warm flow meter or
flow meter. Meter sounds
material in magnet
disassemble and clean.
like it runs but trans-
shield.
mitter does not rotate.
Flow meter operates, but
Transmitter drive
Straighten shaft and
output is erratic.
magnet drags on
check end clearance.
meter body.
Discontinued