Page 25

Command

Response

Description

Q22

A22 a

Query Totalizer Pulse Output Speed
where

a = 0 - No Pulse

= 1 - Pulse Fast
= 2 - Pulse Medium
= 3 - Pulse Slow

L23 aaaa

A

Load Totalizer Output Time
where

aaaa = Output Time

Q23

A23 aaaa

Query Totalizer Output Time
where

aaaa = Output Time

L24 a

A

Load Totalizer Reset Key Function
where

a = Reset Key Function

= 0 - No Function
= 1 - Reset Totalizer
= 2 - Unlatch Output
= 3 - Reset and Unlatch

Q24

A24 a

Query Totalizer Reset Key Function
where

a = Reset Key Function

= 0 - No Function
= 1 - Reset Totalizer
= 2 - Unlatch Output
= 3 - Reset and Unlatch

L25 a

A

Load Totalizer D.P. Location
where

a = 0 - No Dec. Pt.

= 1 - XXXXXXXXX.X
= 2 - XXXXXXXX.XX
= 3 - XXXXXXX.XXX
= 4 - XXXXXX.XXXX
= 5 - XXXXX.XXXXX

Q25

A25 a

Query Totalizer D.P. Location
where

a = 0 - No Dec. Pt.

= 1 - XXXXXXXXX.X
= 2 - XXXXXXXX.XX
= 3 - XXXXXXX.XXX
= 4 - XXXXXX.XXXX
= 5 - XXXXX.XXXXX

L31 aa

A

Load Rate meter Smoothing
where

aa = Smoothing Fact. (05 - 75)

(Must be in steps of 5)

Q31

A31 aa

Query Rate meter Smoothing
where

aa = Smoothing Factor

RS-485 SERIAL COMMANDS