beautypg.com

Figure 4, Figure 5 – Mallory Ignition Mallory COMP PUMP ELECTRIC FUEL PUMP SERIES 110_140 User Manual

Page 4

background image

FLOW RATE GPH

25

50

75

100

125

1.5

3.0

4.5

6.0

7.5

PRESSURE PSI

COMP PUMP

®

SERIES 110 FLOW VS. PRESSURE @12.5VDC

(FLOW INCREASES AS PRESSURE DECREASES)

FLOW RATE GPH

30

60

90

120

150

3

6

9

12

15

PRESSURE PSI

COMP PUMP

®

SERIES 140 FLOW VS. PRESSURE @12.5VDC

(FLOW INCREASES AS PRESSURE DECREASES)

1 JAM NUT
2 BYPASS PLUG
3 BYPASS SPRING
4 SCREW, FUEL CHAMBER (2)
5 BYPASS PLUNGER
6 PAD, BYPASS PLUNGER
7 SCREEN, FLAME ARRESTER
8 FUEL CHAMBER
9 GASKET, FUEL CHAMBER

10 PORT PLATE

11 GEROTOR

12 O-RING
13 GEROTOR HOUSING
14 MOTOR

MALLORY IS A DIVISION OF THE MR. GASKET PERFORMANCE GROUP

550 MALLORY WAY, CARSON CITY, NEVADA 89701

(775) 882-6600

FAX (775) 887-4326

www.mrgasket.com

FORM #1022

REV. F (8/00)

MADE IN USA

PRINTED IN USA

4

FIGURE 4

TO ACCESSORIES

IGNITION SWITCH

FROM

VEHICLE

BATTERY

TO COIL (+)

FUSE (7.5 AMP)

FUEL

PUMP

GROUND

12

11

2

3

7

1

4

5

6

8

9

10

13

14

FIGURE 5

BLACK

RED