Flush problems - continued, General problems – Magnum Venus Plastech TALON Gun Internal Mix User Manual
Page 32

Talon Internal Mix Gun Manual
Rev. 10/2013
Page | 32
Flush Problems - continued
Problem
Possible Cause(s)
Recommended
Solution(s)
Solvent leaking from the front of
the gun block or mix chamber
Seal Body O-ring damaged
Replace the Seal Body O-ring
Dirty or Damaged Flush Valve
Body
Clean or Replace the Flush
Valve Body as needed
Solvent Pressure too high
Reduce solvent tank pressure
Flush Seal Body loose or off
Button
Connect and tighten the Flush
Seal Body onto the Button
Resin leaking into the solvent
supply tube / flush tank
Damaged Flush Seal O-ring
Replace the O-ring on the Flush
Seal
Flush Seal Body loose or off
Button
Connect and tighten the Flush
Seal Body onto the Button
General Problems
Problem
Possible Cause(s)
Recommended
Solution(s)
Air leaking around the Air Valve
Damaged O-ring on the valve
Check and replace O-ring on the
Air Valve.
Check inside the handle for
scratches or damage
Air constantly leaking around 3-
Way valve Shaft
Faulty 3-Way Valve
Replace the 3-Way valve
Air constantly leaking from
exhaust port
Faulty 3-Way Valve
Replace the 3-Way valve
Material leaking around the Mix
Chamber
Loose Mix Housing
Tighten the cap screws holding
the mix housing in place
Damaged Mix Housing Seal or
gun block
Replace the mix housing Seal
Check Gun Block for scratches
or damage