Another alternative for RS-485 is to use an RS-232 to RS-485 converter that plugs into the
computer RS-232 receptacle external to the computer and is powered from a +9V DC wall plug-
in adapter. One such unit is the B & B Electronics Model 485OT9L.
-4-
RS - 485 INTERFACE - J3A & J3B
FULL DUPLEX
ISO GROUND
BRX
ARX
ATX
BTX
ISO GROUND
6
5
4
3
2
1
MODEL 485OT9L
TB1
TDB (+) TRANSMIT +
TDA (-) TRANSMIT -
RDA (-) RECEIVE -
RDB (+) RECEIVE +
GND GROUND
RS232 TO 485 CONVERTER
SWITCH SETTINGS FOR MODEL 485OT9L
Baud rate
4800 Baud
-
S1-ON,
S2-OFF
S3-OFF
S4-OFF
9600 Baud
-
S1-0FF,
S2-ON
S3-OFF
S4-OFF
19200 Baud
-
S1-OFF,
S2-OFF
S3-ON
S4-OFF
Echo
-
S5-OFF
2-wire/4-wire -
S6-OFF,
S7-OFF
Termination
-
S8-OFF
Driver Control -
JP1-Jumper on SD
RS - 485 INTERFACE - J3A & J3B
HALF DUPLEX
ISO GROUND
ATX/ARX
BTX/BRX
ISO GROUND
6
5
4
3
2
1
MODEL 485OT9L
TB1
TDA (-) TRANS,RCV -
TDB (+) TRANS,RCV +
GND GROUND
RS232 TO 485 CONVERTER
SWITCH SETTINGS FOR MODEL 485OT9L
Baud rate
4800 Baud
-
S1-ON,
S2-OFF
S3-OFF
S4-OFF
9600 Baud
-
S1-0FF,
S2-ON
S3-OFF
S4-OFF
19200 Baud
-
S1-OFF,
S2-OFF
S3-ON
S4-OFF
Echo
-
S5-ON
2-wire/4-wire
-
S6-ON,
S7-ON
Termination
-
S8-OFF
Driver Control -
JP1-Jumper on SD
- QLS Quad Output 4-20 mA Current Loop - Datasheet (3 pages)
- QLS Quad Output 4-20 mA Current Loop - Manual (8 pages)
- LTS6 - Datasheet (3 pages)
- LTS6 - Manual (24 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Duty Cycle Input (4 pages)
- LT SERIES TRANSMITTERS PULSE INPUTS (40 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Position or Rate from Quadrature Encoders (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Average Time of Periodic Events (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Time of Single or Accumulated Events (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for AC Phase Angle & Power Factor (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Ratio (4 pages)
- LT: 4-20 mA & Serial Data Transmitter-Totalizer for 0-1 mA, 4-20 mA or 0-10V Process Signals (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Dual Channel Pulse Totalizer Input (4 pages)
- LT: Ethernet & 4-20 mA Output Transmitter for Frequency, Rate or Period Input (4 pages)
- LT SERIES TRANSMITTERS ANALOG INPUT (40 pages)
- LT: 4-20 mA Current Loop Transmitter for Resistance Input in Ohms (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Pt100, Cu10 and Ni120 RTD Input (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Thermocouple Types J, K, T, E, N, R, S (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Load Cell & Microvolt Signals (4 pages)
- LTE SERIES TRANSMITTERS ANALOG INPUT (40 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Strain Gauge & Potentiometer Input (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Process Signals (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for AC RMS Voltage or Current Input (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for DC Voltage or Current Signals (4 pages)
- LTE SERIES TRANSMITTERS PULSE INPUT (40 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Duty Cycle Input (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Position or Rate from Quadrature Encoders (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Average Time of Periodic Events (5 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Time of Single or Accumulated Events (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for AC Phase Angle & Power Factor (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Ratio (5 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter & Totalizer for 0-1 mA, 4-20 mA or 0-10V Signals (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Dual Channel Pulse Totalizer Input (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Frequency, Rate or Period Input (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Resistance in Ohms (4 pages)
- LTE: Ethernet & 4-20 mA Output RTD Transmitter for Pt100, Cu10 and Ni120 RTD Input (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Thermocouple Types J, K, T, E, N, R, S (4 pages)
- LTE: Ethernet & 4-20 mA Transmitter for Load Cell & Microvolt Signals (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Process Signals (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for AC RMS Voltage or Current (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for DC Voltage or Current (4 pages)
- LTSE6 - Manual (25 pages)
- LTSE6 - Datasheet (3 pages)
- MAGNA Series Large Digit Displays (4 pages)
- M-35 Microminature Process Meter (2 pages)