The measurement data format with both of these parameters set consists of 10 characters:

+999.99A

* * * = optional character

The coded character preceding the carriage return is a letter from A to P. It supplies the alarm,
overload and zero-blanking status of the meter according to the following table:

Alarm Status

Zero Blanking

No Zero Blanking

No overload

Overload

No overload

Overload

Neither Alarm set

A

E

I

M

Alarm 1 set only

B

F

J

N

Alarm 2 set only

C

G

K

O

Both Alarms set

D

H

L

P

For example, a coded character “G” indicates that Alarm 2 only is set, the DPM is in the overload
condition and zero blanking has been selected. This information is useful when the output data is
supplied to a computer for listing and analysis or when it is supplied to a Remote Display in a
Master-Slave configuration.

The Counter and Scale meter are capable of supplying more than 1 measurement value each
reading. In the counter, depending on the selected Function, there can be 1,2 or 3 active
measurement values plus a peak value. The scale meter can transmit net, gross and peak. The
values transmitted are selected by “Ser 3”

These values are sent in a continuous string with no space between them. If Menu item “Ser 3” “Digit
5” = 1, the termination characters of and optional appear at the end of each value. If
it = 0 then the termination characters appear only once at the end of the string. In either case, the
coded character, if included, appears at the end of the last value only.