Technical description – Impulse 3622 User Manual
Page 8

Technical
Description
Sealevel Systems PC-COMM+232 Page
6
Technical Description
The PC-COMM+232 provides two RS-232 serial ports utilizing XR16C850
UARTs (Universal Asynchronous Receiver Transmitter). The XR16C850 is
compatible with the 16550 UART. The ‘850 is an enhanced UART with 128
byte FIFOs, automatic hardware/software flow control and the ability to handle
much higher data rates than standard UARTs.
Connector Pin Assignments for RS-232 (DB-9 Male)
Signal Name DB-9*
Mode
GND Ground
5
TD Transmit
Data
3
Output
RTS
Request To Send
7
Output
DTR
Data Terminal Ready
4
Output
RD Receive
Data
2 Input
CTS
Clear To Send
8
Input
DSR
Data Set Ready
6
Input
CD Carrier
Detect
1 Input
RI Ring
Indicator
9
Input
* Note: These assignments meet EIA/TIA/ANSI-574 DTE for DB-9 type
connectors.
Technical Note: Please terminate any control signals that are not going to be
used. The most common way to do this is connect RTS to CTS and RI. Also,
connect DCD to DTR and DSR. Terminating these pins, if not used, will help
insure you get the best performance from your adapter.