Hardware Setup
Address Selection
The SIO-104+16.485 occupies 16 consecutive I/O locations. The DIP-switch (SW1)
is used to set the base address for these locations. Be careful when selecting the base
address as some selections conflict with existing PC ports. The following table
shows the addressing options available. If different address options are required,
please contact Sealevel Systems Technical Support about a custom option.
Switch Settings
SW1-1
OFF
OFF
OFF
ON
ON
ON
ON
SW1-2
OFF
ON
ON
OFF
OFF
ON
ON
SW1-3
ON
OFF
ON
OFF
ON
OFF
ON
Ports Addresses
Port 1
300
400
500
600
1500
3220
4220
Port 2
308
408
508
608
1508
3228
4228
Port 3
310
410
510
610
1510
3230
4230
Port 4
318
418
518
618
1518
3238
4238
Port 5
320
420
520
620
1520
3240
4240
Port 6
328
428
528
628
1528
3248
4248
Port 7
330
430
530
630
1530
3250
4250
Port 8
338
438
538
638
1538
3258
4258
Port 9
340
440
540
640
1540
3260
4260
Port 10
348
448
548
648
1548
3268
4268
Port 11
350
450
550
650
1550
3270
4270
Port 12
358
458
558
658
1558
3278
4278
Port 13
360
460
560
660
1560
3280
4280
Port 14
368
468
568
668
1568
3288
4288
Port 15
370
470
570
670
1570
3290
4290
Port 16
378
478
578
678
1578
3298
4298
Note: Setting SW1-1, SW1-2, and SW1-3 all to OFF disables the card, which may be useful
for troubleshooting purposes.
Interrupt Configuration
The board is set up to always share interrupts. There is a jumper labeled “PD” which
is located at (E1) on the SIO-104+16.485. Setting this jumper enables a 1K-ohm
pull-down (biasing) resistor required on one adapter when sharing interrupts. The
jumper should always be enabled on single SIO-104+16.485 installations (non-
shared mode). In multiple SIO-104+16.485 installations, only one board should have
the jumper enabled.