DIP SWITCH FUNCTIONS

TIMER

TIMER switch “ON” activates the TIMER. See page 25 for details
.

RADIO

RADIO switch “ON” allows the radio receiver to override the timer. See
page 25 for details.

OSC

OSC switch “ON” allows the radio receiver to stop and reverse the gate
in any direction. During a cycle the first signal stops gate, a second
signal reverses gate.
th

FAIL SF/SC

This is to set the operator as fail-safe or fail secure.

ON for Fail-safe: on power failure, board will monitor battery voltage to

make sure gate opens before battery drains out completely.

OFF for Fail-secure: on power failure gate will run until battery

is low and either stay open or close depending what position it is when battery is low.

1-PASS

This is a true one pass

, anti-tailgating feature. This feature may only be used with safety loops. With this switch in the “ON

position, the gate will open until one car passes

the safety loops then it will stop and close. If a second car pulls on the loop

the gate will stop the car must then back off the loop before the gate will close.

SLAVE

This feature is used on master/slave setups. Set slave switch “

ON” on slave machine, all other switches “OFF”. Set slave

switch to the “OFF” position on master machine. Set other function switches on master machine as desired. See page 21 for

more details on

master/slave connections and settings.

AUTO OPEN

This feature is to automatic open the gate on power interruption. It is a very particular feature used in areas where the fire
department requires the gate to open automatically after a power outage. Set this dip switch “ON” when this feature is
desired.

OPEN L/R

This feature is to set the direction the operator will open. See page 12 for details.

OFF ON

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

--

--

--

--

--

--

--

--

--

--

--

-O

P

E

N

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

-O

P

E

N

--

--

--

--

--

--

--

--

--

--

--

--

TIMER

RADIO

OSC

FAIL SF/SC

1-PASS

SLAVE

AUTO OPEN

OPEN L/R