MASTER/SLAVE CONNECTION
Use a two wire
shielded cable and run it through a UL listed conduit for master/slave connection. Follow the wiring
diagram as shown below.
Master Board Slave Board
+.....................Positive to Positive...................+
-...................Negative to Negative...................-
Before connecting master/slave gate operators together, test and adjust the limit switches and the ERDs for each operator
as “stand alone” machines.
All accessories must be installed on the master board, no exception.
See page 20 for dip switch settings.