Controlled Products Systems Group 9100-080 User Manual
Page 34
2.6.2 Auxiliary
Terminal
The auxiliary terminal is located on the 4602 circuit board just to the right of main terminals 8 and 9.
Auxiliary terminals are numbered 1 through 5 with the first terminal at the top.
1. OPEN
PHOTO-BEAM
This input is only active when the gate is in the opening cycle. An open photo-beam input
during the opening cycle will cause the gate to stop. The gate will remain stopped until
the photo-beam input is cleared, at which time the gate will resume the open cycle.
2. CLOSE
PHOTO-BEAM
This input is only active when the gate is in the closing cycle. A close photo-beam input
during the closing cycle will cause the gate to stop. The gate will remain stopped until the
photo-beam input is cleared, at which time the gate will resume the close cycle.
3. OPEN
EDGE
This input is only active when the gate is in the opening cycle. An open edge input during
the opening cycle will cause the gate to stop and then reverse.
If the gate reaches the full closed position, the gate will remain closed, ignore any
maintained inputs and enter a soft shutdown condition. NOTE: If the gate was initially
activated by a time clock with a contact closure across the gate operator open input, this
input will be ignored until another input (open loop, reverse loop. etc.) is received by the
gate operator.
If a close edge sensor is activated prior to the gate reaching the full closed position, the
gate will stop and enter a soft shutdown condition.
4. CLOSE
EDGE
This input is only active when the gate is in the closing cycle. A close edge input during
the closing cycle will cause the gate to stop and then reverse.
If the gate reaches the full open position, the timer will automatically close the gate (if it is
turned on). Once the gate starts to close again, if the close edge input is activated a
second time prior to the gate reaching the full closed position, the operator will stop and
reverse and will enter a soft shutdown condition.
If an open edge sensor is activated prior to the gate reaching the full open position, the
gate will stop and enter a soft shutdown condition.
5. COMMON
Common terminal for the secondary entrapment protection device inputs.
Page 34
9100-065-D-5-07