beautypg.com

Section 1 - installation, 1 specifications – Controlled Products Systems Group 9100-080 User Manual

Page 15

background image

SECTION 1 - INSTALLATION

Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with
the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your
installation is performed in an efficient and professional manner.

The proper installation of the vehicular slide gate operator is an extremely important and integral part
of the overall access control system. Check all local building ordinances and building codes prior to
installing this operator. Be sure your installation is in compliance with local codes.

1.1 Specifications

Class of Operation:

Class I, II, III, IV

Type of Gate:

Vehicular Slide Gates Only

Horsepower: 1/2

H.P.

Voltage / Phase:

115 VAC Single-phase only

Current: 5.4

amps

Max Gate Weight:

1000 Lbs.

1

Max Gate Length:

30 Ft.

1

Cycles / Hr:

60/Hr

Speed:

Approximately 1 Ft./Sec.

Entrapment Protection:

Primary – Inherent (Type A)

Secondary – Provision for connection of a non-contact

sensor (Type B1) and/or a contact sensor (Type B2).

Secondary entrapment protection devices are not supplied

with the operator and must be ordered separately.

Note 1: Assumes gate is in good working condition installed

on a level surface.

14.75

11.5

12

24

Figure 1

9100-065-D-5-07

Page

15