Photocells connections – Controlled Products Systems Group 104572 User Manual

Page 13

background image

FSW
STP CL OP

How to connect Normally Open contacts.

(Connect them in parallel)

How to connect Normally Close contacts.

(Connect them in series)

The photocells must be connected depending on which area

they must protect. (See Fig. A5)

Closing Safety D : These photocells protect the area covered

by the gate during the closing movement. They have no effect

during the opening movement.

Opening Safety B-C : These photocells protect the area covered

by the gate during the opening movement. They have no effect

during the closing movement.

Opening/Closing Safety A : These photocells protect the area

covered by the gate both during the opening and the closing

movements.

The E024U board allows the connection of several safety devices

(for example photocells). With photocells you can activate the

FAILSAFE function, which, before each movement of the ope-

rator, tests each fotocells. In case the test fails the movement

is inhibited. To activate this function set to ON the dip-switch N.

11 and 12 of DS1, and connect the negative of the transmitter
to the OUT pin (No.9)

.

Fig. A3

Fig. A5

Fig. A4

Connection of a pair of closing photocells and a pair of opening/closing photocells

To use the FAIL-SAFE mode connect the negative power supply of the transmitters to OUT (pin 9), and set dip-

switch 11 and 12 to ON on DS1

Fig. A6

RX= Photocell Receiver

TX= Ptotocell Transmitter

CL= Closing

OP= Opening

3. PHOTOCELLS CONNECTIONS

3.1 CONNECTIONS TO NORMALLY CLOSE (N.C.) PHOTOCELLS

A4

E024U CONTROL BOARD