ENFORCER Outdoor Stand-Alone Keypads

6

SECO-LARM U.S.A., Inc.

1

Connect included diode and metal oxide varistor (MOV) as close as possible and in parallel with an
electric strike. This absorbs possible electromagnetic interference to prevent operation of the strike from
damaging the keypad. Do not connect a diode or MOV when using electromagnetic locks.

2

Output #2 controls the arm/disarm of the alarm control panel. Consult the alarm control panel manual for

more information.

Connecting to a Doorbell

If the keypad is connected to a doorbell, press to activate the doorbell. The doorbell output lasts for 1
second. For instructions on how to program the keypad for doorbell, see page 13, Programming the
Output #2 Function
.

Purple

—Output #2

Blue

—Output #2

12~24

VAC/VDC

Power

Supply

Doorbell

Sample Wiring and Application

(SK-1323 series shown. All examples apply to both the SK-1323 and SK-2323 series.)

Note: Sample applications are based on VDC power supplies.

Connection to Lock Device and Alarm System Arm/Disarm Control

Orange

—Egress Input 1 (N.O.)

Uninsulated Chassis Ground

Black—12~24 VAC/VDC (-)

Red

—12~24 VAC/VDC (+)

Pink

—Output #1 (COM)

Yellow

—Egress Input 2 (N.O.)

—Output #1 (N.O.)

Aqua

—Output #1 (N.C.)

Blue

—Output #2 (N.O.)

Purple

—Output #2 (COM)

Gray

—Output #2 (N.C.)

To Chassis Ground

Electric Strike

N.O.

N.C.

12~24

VAC/VDC

Power Supply

Alarm

Control

Panel

2

Egress

Button

Egress

Button

Diode1

MOV1

Green

—Common ground (-)