beautypg.com

Controlled Products Systems Group SK-1323-SDQ User Manual

Page 10

background image

ENFORCER Outdoor Stand-Alone Keypads

SECO-LARM U.S.A., Inc 11

6. Exit Programming Mode by pressing again.

4. Exit Programming Mode by pressing .

Programming Output #1

E. Setting the Output #1 Access Mode*

DEFAULT: User card OR user code.

2. Enter .

0

1. Enter Programming Mode by entering the Master Code twice.

0 0

User card ONLY

Either user card OR user code (DEFAULT)

0 1

3. Enter one of the following:

0 2

User card AND user code

1. Enter a user ID number.

Each Output #1 user can be programmed to have a user code and a user card.*

A. User Code Only

4. To program the next user, repeat from step 1 in section A, B, or C.
5. Exit Programming Mode by pressing .

2. If the left LED is red, previous user data exists. Clear it by entering . The keypad will beep in

confirmation and the left LED will turn green.

3. Enter a new user code.

(

to

)

0 0 0

9 9 9

Note – For all of the following programming functions, the keypad must be in Programming Mode. To enter
Programming Mode, enter the Master Code twice.

Note: Deleting all users is recommended before changing the access mode to user card with user

code. See page 14, Deleting All Users.

*SK-2323-SPQ and SK-1323-SPQ only.

D. Program the Master Card (SK-1323-SPQ and SK-2323-SPQ only)

In addition to a Master Code, a Master Card can also be programmed. Swiping a Master Card will give
direct access to Programming Mode.

1. Enter Programming Mode by entering the Master Code twice. (Default Master Code is 1234)
3. On the keypad, enter .

7

4. Swipe a proximity card (PR-K1S1A or similar). This card is now the Master Card.
5. Exit Programming Mode by pressing .

2. If the left LED is solid green and the right LED is flashing orange, a Master card is already

programmed. Clear it by entering . The keypad will beep in confirmation and the left LED
will start flashing green.

1. Enter a user ID number.

4. Return to Programming Mode by pressing .

3. Swipe a new user card.

5. To program the next user, repeat from step 1 in section A, B, or C.

B. User Card Only*

2. If the left LED is red, previous user data exists. Clear it by entering . The keypad will beep in

confirmation and the left LED will turn green.

(

to

)

0 0 0

9 9 9

This manual is related to the following products: