Resetting the Keypad
NOTE: Resetting the keypad will cause some or all programmed data to be lost. Do not
perform either of these steps unless it is absolutely necessary.
Deleting All Users
Enter:
8 8 8
IMPORTANT: Once key entry is made, all user codes and user cards will be deleted and the keypad will return to
Programming Mode. The Master Code and all other programming settings will remain the same. To restore factory
settings, see Restore Factory Settings below.
Restore Factory Settings
Enter:
8 9 9
IMPORTANT: Once key entry is made, keypad will return to factory default settings. No users will be present and the
Master Code will be 1234. For SK-2323-SPQ and SK-1323-SPQ, Output #1 Access Mode will be set to user codes or user
cards.
Factory Defaults
Code Length
4 digits
Master Code
1234
Output #1 Access Mode*
User codes OR user cards
Output #1 User Codes
None
Output #2 User Codes
None
Output #1 Timer
1 second
Output #2 Timer
1 second
Output #2 Function
User codes
Tamper Alarm
OFF
Manually Resetting the Master Code
If the Master Code has been forgotten or does not work, the following steps can be taken to reset the
Master Code:
1. Disconnect power from the keypad.
2. Hold down the key.
3. While holding the key, reconnect the power.
4. After 3 seconds, the keypad will beep to confirm a successful reset.
#
#
Note: Manually resetting the Master Code will only reset the Master Code. It will not affect the Master
Card, User Code, or any other saved data. To delete the Master Card, see page 12, Deleting or Changing
the Master Card.
Note: The Master Code will reset depending on the programmed code length. These will be the new
Master Codes after the code length is reset:
Code Length
New Master Code
2 digits
12
3 digits
123
4 digits
1234
Code Length
New Master Code
5 digits
12345
6 digits
123456
*SK-1323-SPQ and SK-2323-SPQ only