Exb serial rear panel, Figure 4 exb-serial module rear panel – CTI Products EXB-232 Asynchronous Serial System Extender User Manual
Page 13

68-11089-115
9
"CMD" button -- currently not used.
"OPTION A" switches --
1-4
Reserved. All switches must be UP.
5
Normal Systems:
leave Up
Custom Engineered Systems, set as indicated in Custom Documentation
6-8
Reserved. All switches must be UP.
EXB Serial Rear Panel
CA-80286-105
1
2 3 4
ON
89
7
AB
C
D
EF
01
23
4
5
6
89
7
AB
C
D
EF
01
23
4
5
6
89
7
AB
C
D
EF
01
23
4
5
6
OPTION B
PORT 1
PORT 2
BAUD 1 BAUD 2
1
2
3
4
6
7
8
9
5
1
2
3
4
6
7
8
9
5
89
7
AB
C
D
EF
01
23
4
5
6
MODE 1
MODE 2
Figure 4 EXB-Serial Module Rear Panel
“PORT 1” and “PORT 2” connectors -- Provide for connecting up to two external RS-232
devices to the EXB-Serial module.
“BAUD 1” and “BAUD 2” switches -- Correspond to PORT 1 and PORT 2 connectors and
allow either disabling the port for use or enabling it at a specific baud rate.
BAUD Switch
Position
Selected Baud
Rate
0
port disabled
1
1200
2
2400
3
4800
4
9600
5
19.2 K
6
38.4 K
7
57.6 K
8
115.2 K
“MODE 1” and “MODE 2” switches -- Reserved. These switches must be set to 0.