CIB Hardware Reference

Comparator Wiring Lists

CTI Products, Inc.

68-10854-135

29

7.5.1

JPS Voter Modifications for Monitoring Voted Out using Channel Select In
The JPS SNV-12 Voters with firmware version 1.08 or lower do not pull the Vote
Out line to ground when a receiver channel is selected externally through the
Select In lines (terminal 11). the Voted Out line goes low only when the SNV-12
votes the Receiver through the standard voting process. Votes are not indicated
due to a force select input.

To get a “VOTE” indication when force-voting (force selecting) a receiver site,
simply connect a standard diode (type 1N914 or similar) to the SNV-12 voter
module as shown in Table 21. This modification will allow the CIB module to
monitor the Voted Out signal when a receiver site is selected externally via the
Select In terminal. Do a modification for each voter module used with a CIB.

SNV-12 Pin

Function

DIODE

11

SELECT

CATHODE

15

VOTED OUT

ANODE

Table 21 - Diode Connection for Force-Vote Monitoring on JPS SNV-12