Ctek products are protected by charging programs, Support – CTEK MXTS 70 50 User Manual
Page 9

10 • EN
SUPPORT
CTEK offers a professional customer support: www.ctek.com.
for latest user manual see www.ctek.com.
By e-mail: [email protected], by telephone: +46(0) 225 351 80,
by fax +46(0) 225 351 95.
CTEK prodUCTS ArE proTECTEd by
ChARGING PROGRAMS
STEP 1 DESULPhATION
Detects sulphated batteries. pulsing current and voltage, removes sulfates from
the lead plates of the battery restoring the battery capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents charging a defect battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
STEP 5 ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need
to be replaced.
STEP 6 RECOND
Choose the Ca/Ca program to add the recondition step to the charging program.
This step can also be selected separately by choosing the BooST-program. During
the recondition step voltage increases to create controlled gassing in the battery.
gasing mixes the battery acid and gives back energy to the battery.
STEP 7 FLOAT
This step maintains the battery voltage by providing a constant voltage charge. This
step can also be selected separately by choosing the Supply-program and then it
is possible to select different voltage settings.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery
voltage and gives a pulse when necessary to keep the battery fully charged.
dESULpHATIoN
SoFT STArT
bULK
AbSorpTIoN
ANALySE
rECoNd
FLoAT
pULSE
V
o
LT
A
GE (V)
11
7
2
3
4
5
6
8
CU
rr
ENT (A)
NoRmAl
15.8v
31.6V
50A until
12.6v
25.2V
increasing voltage to
14.4v
28.8V
50A
14.4v
28.8V
Declining current
Checks if voltage
drops to below
12v
24V
13.6V
27.2V
Max 50A
12.7–14.4v
25.4–28.8V
50–2A
AGm
15.8v
31.6V
50A until
12.6v
25.2V
increasing voltage to
14.7v
29.4V
50A
14.7v
29.4V
Declining current
Checks if voltage
drops to below
12v
24V
13.6V
27.2V
Max 50A
12.7–14.4v
25.4–28.8V
50–2A
Ca/Ca
15.8v
31.6V
50A until
12.6v
25.2V
increasing voltage to
14.7v
29.4V
50A
14.7v
29.4V
Declining current
Checks if voltage
drops to below
12v
24V
Max 15.8v
Max 31.6V
1.5A
13.6V
27.2V
Max 50A
12.7–14.4v
25.4–28.8V
50–2A
BooST
increasing voltage to
15.8v
31.6V
1.5A
Selectable timer,
initially 8h. Max 24h.
Supply
Selectable
13.6; 14.0;
14.4; 14.8v
27.2; 28.0
28.8; 29.2V
70A**
Time limit:
8 hours
20 hours
8 hours
3 minutes
2 hours or 6 hours
depending on
battery voltage at
charge start
10 days*
Max 1h pulse
*) Supply program is not time limited
**) For 12V only, max current is delivered for 30 seconds followed by a 90 second rest time.
The 30 second counter starts when current has exceeded 50A. 50A is delivered continuously.
20019214A
2012–05–30
patents
designs
Trade marks
EP10156636.2 pending
rCD 509617
TMA 669987
uS12/780968 pending
uS D575225
CTM 844303
EP1618643
US D580853
CTM 372715
uS7541778
US D581356
CTM 3151800
EP1744432
uS D571179
TMA 823341
EP1483817 pending
RCD 321216
CTM 1025831
SE524203
RCD 000911839
CTM 405811
US7005832B2
rCD 081418
CTM 830545751 pending
Ep1716626 pending
rCD 001119911-0001
CTM 1935061 pending
SE526631
rCD 001119911-0002
V28573IP00
US7638974B2
rCD 081244
CTM 2010004118 pending
Ep09180286.8 pending
RCD 321198
CTM 4-2010-500516
uS12/646405 pending
RCD 321197
CTM 410713
EP1483818
ZL 200830120184.0
CTM 2010/05152 pending
SE1483818
ZL 200830120183.6
CTM1042686
uS7629774B2
RCD 001505138-0001
CTM 766840 pending
Ep09170640.8 pending
RCD 000835541-0001
US12/564360 pending
RCD 000835541-0002
SE528232
D596126
SE525604
D596125
RCD 001705138-0001
US D29/378528 pending
ZL 201030618223.7
US RE42303
US RE42230
20019214A Manual MXTS70, All languages, Print file_003.indd 10
2013-08-19 13:22:24