8 • EN

INDICATION LAMPS, DISPLAYS

AND ERRORCODES

SETTINGS BEFORE START:

DISPLAY (V)

indicates voltage set

options: 12/24 volts

DISPLAY (A)

indicates current set

options: 70/50/40/30/20/10A in 12v setting

options: 50/40/30/20/10A in 24v setting

70A could only be selected for Supply program.

DISPLAY (h)

indicates which parameter to set

options: U/SU/A/ /
U

= Nominal voltage

SU

= Supply voltage

A

= Current limit

= Temperature compensation

= recond time in BooST program

DISPLAY (Ah & info)

Displays error codes

REAL TIME INDICATION DURING ChARGING:

DISPLAY (V)

Displays output voltage

DISPLAY (A)

Displays output current

DISPLAY (h)

Alt. 1. Displays total elapsed charging time (minutes/hours)

Alt. 2. Displays time elapsed until error occured

DISPLAY (Ah & info)

Alt.1. Displays total charge delivered since start (minutes/hours)

Alt.2. Displays error codes together with Error lamp

ERROR CODES:

E01

REVERSE POLARITY

Connect the charger according to “quickguide”

E02

OVER VOLTAGE

Battery voltage to high for the chosen charging program, check

battery voltage.

E03

TIME OUT STEP 1: DESULPhATION

restart the charger. if charging is still being interrupted the bat-

tery is seriously sulphated and may need to be replaced.

E04

TIME OUT STEP 2: SOFT START

restart the charger. if charging is still being interrupted the battery

can not accept charge and may need to be replaced.

E05

TIME OUT STEP 5: ANALYSE

restart the charger. if charging is still being interrupted the bat-

tery can not keep charge and may need to be replaced.

E06

BATTERY OVERhEATED

The battery is too hot to charge. The battery is damaged and

may need to be replaced.

E07

LOW BATTERY VOLTAGE IN SUPPLY PROGRAM

Battery voltage too low or too large consumers connected. Check

if 12v battery connected in 24v battery setting or disconnect

large consumers.

E08

hIGh CURRENT IN SUPPLY PROGRAM

Check if clamps are short circuited or connected reversed polarity.

E99

OVER VOLTAGE PROTECTION

if battery voltage is below 17v the Error lamp is lit when 24v

setting has been selected.

Alt 1. press STArT/STop button to charge with 12v setting.

To set the parameters for customized charging proceed with

“ChArgiNg” step 6 to 9

Alt 2. press iNCrEASE button to change to 24v setting. press

STArT/STop button to resume. To set the parameters for custom-

ized charging proceed with “ChArgiNg” step 6 to 9.

10-70

12/24

E01-E99

E01

INDICATION LAMPS:

START/STOP LAMP

indicates that charging has not started or has been interrupted.

press STArT/pAuSE-button to start/resume.

POWER LAMP

indicates that mains supply is connected.

ERROR LAMP

indicates that a fault has occurred.

Se Error CoDES for description.

press STArT/pAuSE-button to clear error and interrupt charging.

TEMPERATURE SENSOR LAMP

indicates that the temperature sensor is activated.

voltage is automatically adjusted to optimize charge at

ambient temperature.