Clock Audio MR 88 User Manual
Page 14

Page 14
Get Channel Meters and Status
Command 0x0B.
Byte
Name
Value
Detail
1
Address
Byte
Address
2
Command
0x0B
Get Status
Response from MR88
Byte
Name
Value
Detail
1
Address
Byte
Address
2
Command
0x8B
Get Status Ack
3
Channel 1 Meter
0xC4 – 0x0D
-60 dB – +13 dB
4
Channel 2 Meter
0xC4 – 0x0D
-60 dB – +13 dB
5
Channel 3 Meter
0xC4 – 0x0D
-60 dB – +13 dB
6
Channel 4 Meter
0xC4 – 0x0D
-60 dB – +13 dB
7
Channel 5 Meter
0xC4 – 0x0D
-60 dB – +13 dB
8
Channel 6 Meter
0xC4 – 0x0D
-60 dB – +13 dB
9
Channel 7 Meter
0xC4 – 0x0D
-60 dB – +13 dB
10
Channel 8 Meter
0xC4 – 0x0D
-60 dB – +13 dB
11
Output A Meter
0xC4 – 0x0D
-60 dB – +13 dB
12
Output B Meter
0xC4 – 0x0D
-60 dB – +13 dB
13
Enabled
Channels
0x00 – 0xFF
A 1 in the corresponding bit
position indicates that the
channel is detected and on.
Bit 0 = Channel 1
Bit 1 = Channel 2
Bit 2 = Channel 3
Bit 3 = Channel 4
Bit 4 = Channel 5
Bit 5 = Channel 6
Bit 6 = Channel 7
Bit 7 = Channel 8