Parameter
1.2 Begin a new parameter setting
Choose the type of parameter setting
Before beginning a new parameter setting, you must select the application type:
Click in menu 'Parameter,' or in the thumb index 'Parameter' then 'New,' choose your application.
-Open loop
Tension control application by measurement of the diameter
Inertia compensation with analogical line speed information
-Closed loop
Tension control application by measurement of the tension or the torque.
Dancer application (control of the dancer roll position)
-Inertia compensation
Tension control application when inertia becomes dominating in the transitional phases.
-Motor command
Use for intermediate tension control or rewinding application with motor speed control
-Speed follower
Use for rewinding application with motorized clutch. The goal is to control the tension
with the clutch and to control the slipping speed in the clutch to undersize it
Each of these application types requires a different set of parameters, choose the category
corresponding to your use of the QUANTUM.
Modify the parameters
The parameters are divided into three or four menus (according to the application type). Click
on the button of one of these menus to modify the contents of it.
Once the parameter setting is finished, you can save it or send to the regulator.