beautypg.com

Front panel leds, Table 6 – ADTRAN 239 T1 HDSL4 User Manual

Page 15

background image

239 H4R Installation and Maintenance Practice

Front Panel LEDs

61223445L1-5D

9

7. FRONT PANEL LEDS

The ADTRAN 239 H4R provides front panel LEDs to display status information. See

Table 6

for a listing of the

front panel LEDs and their indications.

Table 6. Front Panel LEDs

Unit

Label

Indication

Description

LP1/LP2
NET

!

Off

"

Solid Green

Fast Flashing Green

Slow Flashing Green

"

Solid Yellow

Flashing Yellow

"

Solid Red

Flashing Red

No span power is present
Synchronized with an Signal to Noise Ratio (SNR) margin greater than
the recommended SNR Margin Alarm Threshold
(Flashing 3 times per second) Attempting to synchronize with the
H4TU-C
(Flashing once per second) Synchronized with a SNR margin greater
than the recommended SNR Margin Alarm Threshold, and the attenua-
tion is greater than the user recommended Loop Attenuation Alarm
Threshold
Synchronized with a SNR margin greater than 0 dB but less than the
recommended SNR Margin Alarm Threshold
Synchronized with a SNR margin greater than 0 dB but less than the
recommended SNR Margin Alarm Threshold, and the attenuation is
greater than the user recommended Loop Attenuation Alarm Threshold
Synchronized with a SNR margin of 0 dB
(Flashing once per second) Synchronized with a SNR margin of 0 dB,
and the attenuation is greater than the recommended Loop Attenuation
Alarm Threshold

LP1/LP2
CUST

!

Off

"

Solid Green

Fast Flashing Green

Slow Flashing Green

"

Solid Yellow

Flashing Yellow

"

Solid Red

Flashing Red

No span power is present
Synchronized with an Signal to Noise Ratio (SNR) margin greater than
the recommended SNR Margin Alarm Threshold
(Flashing 3 times per second) Attempting to synchronize with the
H4TU-R
(Flashing once per second) Synchronized with a SNR margin greater
than the recommended SNR Margin Alarm Threshold, and the attenua-
tion is greater than the user recommended Loop Attenuation Alarm
Threshold
Synchronized with a SNR margin greater than 0 dB but less than the
recommended SNR Margin Alarm Threshold
Synchronized with a SNR margin greater than 0 dB but less than the
recommended SNR Margin Alarm Threshold, and the attenuation is
greater than the user recommended Loop Attenuation Alarm Threshold
Synchronized with a SNR margin of 0 dB
(Flashing once per second) Synchronized with a SNR margin of 0 dB,
and the attenuation is greater than the recommended Loop Attenuation
Alarm Threshold

LL/RL

"

Solid Yellow

Flashing Yellow

"

Solid Green

Indicates that a loopback is active at the H4R towards the H4TU-C
H4R is armed but not in loopback
Indicates that a loopback is active at the H4R towards the H4TU-R

239 H4R

1223445L1

LP1

NET

LP2

LP1

LP2

LL RL
(Y) (G)

/

CUST