Local control and status – INSTEON OutletLinc Dimmer (Dual-Band) (2472DWH) Manual User Manual
Page 4
Page 4 of 13 2472D - Rev: 1/21/2014 7:48 AM
Magnet
(faces plug)
1) Turn off the circuit breaker (or remove fuse) supplying power to the outlet location.
2) Remove the existing wallplate from the outlet you are replacing. Then, unscrew the outlet itself and
pull it out from the junction box.
3) Disconnect the wires from the outlet you are replacing. If the wires cannot be detached by unscrewing
them, cut the wires where they enter the switch and then strip ½” of insulation off the ends.
4) Twist together the bare copper OutletLinc wire to the Ground wire with a wire nut.
5) Twist together the white OutletLinc wire to the Neutral wire with a wire nut.
6) Twist the black OutletLinc wire to the Line wire with a wire nut.
7) Ensure all connections are solid with no exposed copper (other than Ground).
8) Carefully install and screw OutletLinc into electrical box, then install Decora trim-plate.
9) Turn circuit breaker back on.
OutletLinc LED will blink
red
for about 1 minute then turn solid
red
.
10) Slip the OutletLinc Dimmer Key over the prongs of
your lamp’s plug so the circular magnet protrusion
faces the lamp’s plug.
11) Plug lamp into top outlet on OutletLinc.
The lamp will turn on and the OutletLinc LED will
turn on
green
.
12) If the lamp does not turn on, turn it on manually using
the lamp’s switch.
13) Tap OutletLinc’s Set button.
Lamp will turn off (if on) and on (if off).
LED will be
green
when lamp is on and
red
when it is off.
Local Control and Status