STEP 8: POUR THE MIXED DISINFECTANT SOLUTION INTO THE 1ST

PRE-FILTER SUMP AND RE-INSTALL.

STEP 9: OPEN THE INLET VALVE AND OPEN THE FAUCET. WHEN

WATER BEGINS RUNNING FROM THE FAUCET AGAIN, CLOSE THE

FAUCET AND ALLOW THE PRESSURE TANK TO FILL FOR 5 - 10

MINUTES. WHEN THE PRESSURE TANK FEELS LIKE IT HAS FILLED,

CLOSE THE INLET SUPPLY VALVE.

STEP 10: ALLOW THE SYSTEM TO SIT WITH THE DILUTED SANITIZING

SOLUTION FOR APPROXIMATELY 20 MINUTES.

STEP 11: OPEN THE FAUCET AND PURGE THE TANK AND SYSTEM OF

THE SANITIZING SOLUTION.

STEP 12: REINSTALL THE MEMBRANE AND REPLACE THE CARTRIDGES.

PURGE THE PRE-CARBON CARTRIDGE OF FINES (as per installation

instructions). OPEN THE INLET SUPPLY NEEDLE VALVE AND ALLOW

SYSTEM TO FILL.

OPEN THE FAUCET AND DISCARD THE FIRST TANK FULL OF WATER.

(IF A NEW MEMBRANE ELEMENT IS INSTALLED A THIS TIME, DISCARD

THE FIRST TWO TANKS FULL OF WATER).