beautypg.com

Start-up procedure – Hydrotech Reverse Osmosis Drinking Water System c_w Booster Pump and Inlet Solenoid User Manual

Page 14

background image

12

Start-Up Procedure

WARNING: To prevent microbiological growth and freezing, this reverse osmosis system contains a preservative

solution which, if ingested, may cause irritation of the gastrointestinal tract, colic, diarrhea or other similar symptoms.

Therefore, 5 gallons (approximately two full tanks) must be drawn from the spigot to flush out the preservative. This

may represent two or three days of running, depending on conditions of the feed water.

The carbon filters require some rinsing to remove carbon fines. The filters will rinse out on their own by allowing the system

to produce 2 full tanks of water and discarding the RO product water. The following procedure may be followed if it is

desired to rinse the filters immediately before producing an RO product water.

a. Disconnect the line from the outlet side of the Pre-Carbon Filter (Sump #2). Direct tubing into a pail or catch basin.

b. Turn on the feed water by opening the needle valve on the feed water saddle valve and catch the water in the pail. The

water rinsing the filter will appear grayish until the fines are rinsed out. When the water returns to clear, close the inlet

water valve. Re-connect the white tubing back into Sump #2. The filters are now rinsed.

c. Turn on feedwater by opening the inlet water valve. Immediately check for any signs of a leak. Correct any problems if

necessary. Turn on storage tank valve.

d. It will not be uncommon to experience air bubbles or dissolved air in the product water. This will disappear after the unit

is in service for a short period of time.

e. The first two full tanks must be discarded to flush the membrane preservative out of the system as well as flush the

carbon fines from the Post Carbon Filter (Sump #3).

Figure 9

Sump #1

Sump #2

Sump #3

Disconnect

tubing from

this elbow