Sanitization Steps

STEP 1: TURN OFF WATER SUPPLY - CLOSE INLET SUPPLY ALL THE

WAY

STEP 2: DEPRESSURIZE SYSTEM - OPEN FAUCET SUPPLY UNTIL ALL

WATER IS EMPTIED

Use a clean drip pan or basin to continue to catch any spilled water remaining

in the housings as you remove the membrane and cartridges.

STEP 3: (Refer to Figures 12, 13 and 14) DISCONNECT THE FEED

TUBE FROM THE MEMBRANE HOUSING MODULE. UNSCREW

THE MEMBRANE HOUSING MODULE END CAP AND REMOVE THE

MEMBRANE ELEMENT. PUT THE MEMBRANE ELEMENT ASIDE ON A

CLEAN DISINFECTED SURFACE.

(Unless the membrane element is being replaced at this time, then discard

the old membrane.)

STEP 4: OPEN THE FILTER SUMPS WITH THE SUMP WRENCH

SUPPLIED AND REMOVE THE CARTRIDGES.

STEP 5: CLEAN THE FILTER SUMPS WITH SOAP AND CLEAN WATER.

USE A CLOTH OR SOFT BRUSH AS REQUIRED. CLEAN THE INSIDE OF

THE MEMBRANE HOUSING AS WELL.

(You may need to pay close attention to the O-Ring seals and re-grease them

afterwards with silicone lubricant)

STEP 6: REINSTALL THE FILTER SUMPS (EXCEPT THE 1ST PRE-

FILTER SUMP) AND THE MEMBRANE CAP AND RECONNECT THE

INLET TUBING TO THE MEMBRANE HOUSING CAP.
STEP 7: MIX UP A DISINFECTANT SOLUTION OF 1 TEASPOON OF

5.25% BLEACH IN 1 GALLON OF WATER.

Figure 12 - RO Membrane Housing

RO Membrane Cap

Figure 13

Figure 14

O-ring