A series, A series technical details – HOMA A Series User Manual
Page 17
A Series
Installation, Operation & Maintenance Manual
A Series Technical Details
Seal Chamber Oil: White Mineral Oil (Chevron Lubricating Oil FM 32, 46, 68)
Seal Oil Volume
ALL N FRAME MOTORS 2.5L
ALL T FRAME MOTORS
2.5L
ALL P FRAME MOTORS
3.7L
CURRENT D MOTORS________0.9L
F, G & H FRAME SEAL OIL VOLUTE VARY BY HP, PLEASE CONSULT FACTORY WITH SPECIFIC
PUMP MODEL.
Seal Oil Level
With pump lying on its side and oil port at 12:00, measure from the top of housing with gasket in place, to
the oil level.
A Series T, N & P motors:
1 1/2” from top of housing to oil level
Minimum Distance between 2 pumps
3” Discharge 4” Discharge 6” Discharge
8” & Larger
AK Min N/A Min 10”
Min 13”
Please consult
AV Min 8” Min 10”
Min 13”
factory for lay-
AMX Min 8” Min 10”
Min 13”
out information
Pg. 17