A series, A series technical details, Resistance readings (ohms) pump weight – HOMA A Series User Manual
Page 16: Approx. (lbs.)
A Series
Installation, Operation & Maintenance Manual
A Series Technical Details
The following is offered as a general guide to values and capacities commonly used.
Resistance Readings (ohms)
Pump Weight
230V 230V 460V
Approx. (Lbs.)
HP / RPM
1 Phase
3 Phase *
3 Phase *
U1 - U2 / U1 - Z2
U-V-W
U-V-W
2.5HP-1750 D 2.2 5.0
1.5 5.0
230 #
2.8HP-1160 T N/A 2.7 5.0
230 #
2.9HP-1750 N 2.2 5.0 3.1 11.0
230 #
2.9HP-1750 T
1.6 4.4 3.1 11.0
230 #
3.5HP-1750 D N/A 1.9 5.5
230 #
3.8HP-1160 T N/A 1.5 2.5
240 #
4.3HP-1750 N 1.5 3.0 1.5 4.2
240 #
4.3HP-1750 T
1.5 4.2
240 #
5.1HP-1750 T
1.1 2.6
N/A
N/A
250 #
5.5HP-1750 N 0.9 1.9 1.3 3.7
250 #
5.5HP-1750 T
N/A 1.3 3.7
250 #
6.2HP-1160 T N/A 1.3 3.7
250 #
6.7HP-1750 T
0.7 1.9
N/A
N/A
260 #
7.5HP-1750 N 0.8 1.5 0.9 2.6
260 #
7.5HP-1750 T
N/A
1.2
3.0
260 #
8.3HP-1160 T N/A 0.9 2.6
260 #
9.7HP-1750 T 0.5
1.4
N/A N/A
260 #
9.8HP-1160 P N/A 0.7 2.2
290 #
10HP-1750 N 0.3 0.9 0.6 1.9
290 #
10HP-1750 T
N/A
0.6
1.9
290 #
11.4HP-1750 T
0.4 0.8
N/A
N/A
290 #
13HP-1750 P N/A 0.5 1.8
350 #
15.3HP-1160 P N/A 0.5 1.1
350 #
20HP-1750 P N/A 0.5 1.1
400 #
21.5HP-1160 P N/A 0.5 1.1
400 #
29HP-1750 P N/A 0.4 0.7
500 #
*Values should be as indicated between any 2 power leads.
Note: Resistance values include 30’cable, and should be within +/- 10% of above value.
Above 30 HP, resistance values between 230 and 460 volt machines vary by less than 0.1 ohm. Consult
factory with specific requirements.
Impeller Bolt Torque: 10MM- 26FT#, 12MM-45FT#, 16MM-108FT#, 20MM- 210FT#
Impeller to Bottom Plate Clearance: (ASC) .020” minimum clearance.
Pump Rotation Right hand (CW) looking down from top of motor, CCW looking at bottom of pump.
Seal Probes: N motor pumps use a 12mm seal probe P motor pumps use 20mm seal probe.
Single wire probes are for non classified areas, and 2 wire probes are for Hazardous areas.
Pg.16