GRP, TP Motor Voltage Change
This procedure will provide you with step by step instructions to
convert 208/230 V operating voltage to 460V in dual voltage motors.
1. Remove pump from service. Disconnect
power supply. Clean and decontaminate
pump prior to working on it. See the
pump Installation, Operation, and
Maintenance Manual for detailed
instructions.
2. With pump in stable, upright position,
remove the 5mm cap screws as
indicated.
3. Carefully lift stator housing 3 inches with
hoist, if available, and check under stator
housing for internal seal probe.
CAREFUL: lifting housing more than 3
inches may damage seal probe. If no
hoist is available, lift by hand and slide
the 2x4s under the housing to hold it up.
Disconnect probe if installed. Carefully lift
stator housing off the pump.
You Need:
5mm Allen Wrench
Wire Cutters
Wire Strippers
Terminal Crimp Tool
Qty 6-Crimpable Wire Nut
Hoist or Qty 2-2x4s