HOMA TP GRP T Motor Voltage Change User Manual
Tp, grp, and t motor voltage change
Publication
88FN2045A
Please Contact Technical Support At 203-736-8890 With Any Additional Questions
Please Be Prepared To Provide Pump Serial Number During Call
Page
1 of 5
TP, GRP, and T Motor Voltage Change
This procedure will provide you with step by step instructions
to convert the operating voltage of dual voltage 3 phase.
You Need:
5 mm Allen Wrench
Wire Cutters
Wire Strippers
Terminal Crimp Tool
Qty 6-Crimpable Wire Nuts 14 to 16 Gage
1. Remove pump from service. Disconnect
power supply. Clean and decontaminate
pump prior to working on it. See the
pump Installation, Operation, and
Maintenance Manual for detailed
instructions.
2. With pump in stable, upright position,
remove the four 5mm cap screws as
indicated.
3. With the cap screws removed, lift the
stator housing off of the pump.