beautypg.com

Important, Manual reset hi-limit instructions – American Dryer Corp. MD-170 User Manual

Page 71

background image

67

I M P O R T A N T

MANUAL RESET HI-LIMIT INSTRUCTIONS

FOR DUAL TIMER OR PHASE 5 WITHOUT HEAT FAULT

(STEAM MODELS ONLY)

This dryer was manufactured with a manual reset tumbler/lint chamber hi-limit thermostat. If the manual

reset thermostat is open prior to the start of the drying cycle, or during the cycle, the dryer will not recognize

the open state of the hi-limit thermostat and will start or continue through the drying cycle with no heat. Manual

reset hi-limit must be reset manually.

This hi-temperature condition may be caused due to a restricted exhaust, poor airflow or improper heating

unit operation.

The location of the manual reset hi-limit is in the lint chamber area.

WARNING: discontinue power to dryer before attempting to reset hi-limit.

IMPORTANT

This dryer is equipped with a

lint chamber hi-limit thermostat
which must be reset manually

WARNING:

Discontinue power to dryer

before attempting to reset hi-limit.

ADC P/N:114501