For models manufactured with Johnson Controls DSI (Direct Spark Ignition)

Module (G760)

Theory Of Operation;

Start the drying cycle. When the gas burner

ignites within the chosen trial for ignition

time (6-seconds), the flame sensor detects

gas burner flame and signals the Direct

Spark Ignition (DSI) module to keep the

gas valve open...as long as there is a call

for heat. The DSI module will

“LOCKOUT” if the gas burner flame is

not sensed at the end of the trial for ignition

period. The trial for ignition period will be

repeated for a total of three (3) retries/trials

(the initial try and two [2] more retries/

trials). If the flame is not sensed at the

end of the third retry/trial (inter-purge period

of 30-seconds) the DSI module will

“LOCKOUT” (L.E.D. [light emitting

diode] flashes).

A steady L.E.D. (light emitting diode)

indicator indicates normal operation.

No L.E.D. (light emitting diode) indicator

indicates a power or an internal failure has

occurred.