2. Technical Gas Data

a. Gas Specifications

b. Gas Connections:

Inlet connection ---- 1-inch N.P.T.

Inlet supply size ----- 1-inch N.P.T. (minimum)

Btu/hr input (per dryer) ----- 550,000 (138,600 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must

be consistent between a minimum of 6-inches (14.92 millibars) and a maximum of 12-inches water

column (29.9 millibars) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so

that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas

valve pressure tap must be a consistent 10.5-inches water column (26.1 millibars). There is no

regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the

source (L.P. tank) or an external regulator must be added to each dryer.

T

YPE OF

G

AS

N

ATURAL

L

IQUID

P

ROPANE

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

Inline Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

10.5 inches W.C.

26.1 mb

Shaded areas are stated in metric equivalents

* Measured at outlet side of gas valve pressure tap when gas valve is on.

T

YP E OF

G

AS

L.P.

Conversion

Kit

Part Number

ADC

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty. D.M.S.*

Part

Number

Qty. D.M.S.*

Part

Number

MDG-170

550,000

138,600

4

#2

140839

4

#29

140820

880978

Shaded area is stated in metric equivalent

* D.M.S. (Drill Material Size) equivalents are as follows:

Natural Gas ............... #2

= .2210" (5.6134 mm)