2. Electrical Service Specifications

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is

affixed to the back of the dryer, at the upper right hand corner. In the case of

208 VAC or 230/240 VAC, the supply voltage must match the electric service

specifications of the data label exactly.

WARNING: 208 VAC and 230/240 Volts ARE NOT THE SAME. Any damage done to dryer

components due to improper voltage connections will automatically VOID THE

WARRANTY.

NOTE: The manufacturer reserves the right to make changes in specifications at any time, without

notice or obligation.

M DG-170 (Gas)

M DS-170 (Steam)

E

LECTRICAL

S

ERVICE

S

PECIFICATIONS

(

PER DRYER

)

IMPORTANT: 208 VAC

AND

230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE:

A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.

B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct

breaker size according to appliance amp draw rating and type of breaker used.

C.

Circuit breakers for 3ø dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

FUSING

CIRCUIT

BREAKER

Dual Element

Time Delay

60 Hz

50 Hz

208

3

27

--

40

60

230/240

3

26

--

40

60

380/400

3/4

--

15

25

30

416

3/4

--

14

20

25

460

3/4

13

--

20

25