beautypg.com

Timing legend, Reversing timer spin/dwell adjustments – American Dryer Corp. MD-170 User Manual

Page 64

background image

60

SECTION VIII

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Timer models have an electric reversing timer in the electric service box which is located in the upper left rear

area of the dryer.

Both the Dwell (stop) Time and basket (tumbler) Spin Time are adjustable by mode selection switches located on

the electronic timer (as noted in the illustration below).

Timing Legend

Spin Time

Switch Position Number

1

2

3

4

5

Time in Seconds*

30

60

90

120

150

Dwell (Stop) Time

Switch Position Number

1

2

3

4

5

Time in Seconds*

5

6

8

10

12

* Values shown are +/- 1 second.