beautypg.com

Electrical data, Electrical connections, K factors – Burkert Type 8012 User Manual

Page 23

background image

23

Technicaldata

Type 8012

6.3.3. electrical data

Power supply

12-36 V DC, filtered and regulated

Current consumption max. 60 mA (at 12 V DC for the version

with current output - no load)

Protection against
polarity reversal

yes

Protection against
spike voltages

yes

Protection against
short circuits

yes, for the pulse output

Pulse output

transistor, NPN by default (can be confi-
gured as PNP, on request), open collector,
700 mA max., NPN output: 0,2-36 V DC
and PNP output: supply voltage, frequency
up to 300 Hz (frequency = K factor x flow
rate). Configurable on request

Current output
(depending on
version)

• max. loop

impedance

4-20 mA, sinking wiring by default, equals
the rotation frequency of the paddle-wheel
(by default). Configurable on request

• 1125 W at 36 V DC
• 650 W at 24 V DC
• 140 W at 12 V DC

6.3.4. electrical connections

Version

type

With a cable gland Cable, 1 m

With a fixed
connector

5-pin M12 fixed connector, adjustable in
position

6.3.5. K factors

The K factors have all been determined in the following reference
conditions:
medium = water, water and ambient temperatures 20 °C, min. upstream
and downstream distances respected, appropriate pipe dimensions

Two versions of the S012 in DN15 and DN20 exist, having
different K factors.
Only version 2, identified by the "v2" marking, is available
from March 2012. The "v2" marking can be found:
• on the bottom of the DN15 or DN20 fitting in plastic:

V2

• on the side of the DN15 or DN20 fitting in metal:

V2

English