Burkert Type S030 User Manual
Page 8
28
Material
Type of connections and
standard
K factors (pulse/
litre)
DN6 DN8 DN15
Stainless steel
Weld ends acc. to:
SMS 3008
-
-
-
BS 4825 / ASME BPE
-
-
-
DIN 11850 Rg2
-
278 106
EN ISO 1127 / ISO
4200
-
-
106
External threads acc. to:
SMS 1145
-
-
-
G
440
278 106
Internal threads acc. to:
G, Rc, NPT
-
-
106
Clamp acc. to:
SMS 3017 / ISO 2852
-
-
-
BS 4825 / ASME BPE
-
-
-
DIN 32676
-
278 106
ISO (pipe EN ISO 1127/
ISO 4200)
-
-
106
English
29
K factors (pulse/litre)
DN15
v2
1)
DN20 DN20
v2
1)
DN25 DN32 DN40 DN50 DN65
-
-
-
66,9 -
31,1 19,9 11,4
-
106
74,5 66,9 49,0 31,1 19,9 11,4
74,5 106
74,5 66,9 49,0 31,1 19,9 -
74,5 66,5 -
49,0 31,8 19,8 11,4 -
-
-
-
66,9 -
31,1 19,9 -
74,5 66,5 -
49,0 31,8 19,8 11,4 -
74,5 66,5 -
49,0 31,8 19,8 11,4 -
-
-
-
66,9 -
31,1 19,9 11,4
-
106
74,5 66,9 -
31,1 19,9 11,4
74,5 106
74,5 66,9 -
31,1 19,9 -
74,5 66,5 -
49,0 31,8 19,8 11,4 -
1)
See page 27.
English
29
30
Material
Type of connections and
standard
K factors (pulse/
litre)
DN6 DN8 DN15
Stainless
steel
Flanges acc. to:
EN 1092-1 (ISO PN16)
ANSI B16-5-1998
JIS 10K
440
-
106
Brass
All
440 278 106
PVC
All
440 278 116
PP
All
-
-
110
PVDF
All
440 278 118
English
31
K factors (pulse/litre)
DN15
v2
1)
DN20
DN20
v2
1)
DN25 DN32 DN40 DN50 DN65
74,5 66,5 -
49,0 31,8 19,8 11,4 -
74,5 66,5 -
49,0 31,8 19,8 11,4 -
84,7 75,3 -
52,9 28,5 17,3 10,2 -
89,9 74,2 -
52,9 28,4 17,4 10,1 -
90,3 78,0 -
57,0 31,7 19,0 10,9 -
1)
See page 27
7. inSTAllATion
Safety instructions
danger
risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut-off the pressure
and drain the pipe before loosening the process
connections.
English
31