Burkert Type S030 User Manual
Page 11
40
installing a clamp fitting
→
Make sure the seals are in good condition.
→
Place seals adapted to the process (temperature,
fluid type) in the grooves of the Clamp fitting.
→
Fix the Clamp fitting to the pipe by means of a clamp collar.
installing a flange fitting
→
Make sure the seals are in good condition.
→
Place seals adapted to the process (temperature,
fluid type) in the grooves of each connection.
Make sure the seal remains in the groove while
tightening the flange.
→
Tighten the flange to fix the fitting to the pipe.
English
41
8. mAinTenAnce
Safety instructions
danger
risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut-off the pressure
and drain the pipe before loosening the process
connections.
risk of injury due to high fluid temperatures.
• Use safety gloves to handle the fitting.
• Stop the circulation of fluid and drain the pipe before
loosening the process connections.
• Keep all easily flammable fluid or material away from the
fitting.
risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident preven-
tion and safety relating to the use of aggressive fluids.
English
41
42
Warning
risk of injury due to non-conforming maintenance.
• Maintenance must only be carried out by qualified and
skilled staff with the appropriate tools.
• Ensure that the restart of the installation is controlled
after any interventions.
cleaning
note
the fitting may be damaged by the cleaning product.
• Clean the fitting with a cloth dampened with water or
a detergent compatible with the materials the fitting is
made of.
English
43
9. SpARe pARTS And
AcceSSoRieS
attention
risk of injury and/or damage caused by the use of
unsuitable parts.
Incorrect accessories and unsuitable spare parts may
cause injuries and damage the fitting and the sur-
rounding area.
• Use only original accessories and original spare parts
from Bürkert.
Accessories
order code
certificate
Certificate 3.1
440 790
Certificate 2.2
440 789
Roughness certificate
444 898
Calibration certificate
550 676
FDA approval
449 788
English
43